Low Voltage AC Motor Guide: How to Choose Between IE3, IE4 and IE5

Oct 22, 2026 Leave a message

Helen Wang
Helen Wang
I lead our Human Resources department, focusing on employee development and company culture. My goal is to create a positive work environment that fosters growth.

A Low Voltage AC Motor often runs for years without stopping. Over that time, the electricity it consumes costs far more than the motor itself. That is why the efficiency class you pick on day one matters more than most buyers expect.

This guide explains what IE3, IE4 and IE5 really mean, how much energy you can save with a worked example, what current regulations say, and which checks to make before placing an order.

 

 

What Is a Low Voltage AC Motor?

 

A Low Voltage AC Motor is a three-phase alternating-current motor designed for supply voltages below 1,000 V. Typical ratings are 380 V, 400 V or 480 V at 50 Hz or 60 Hz. These motors drive pumps, fans, compressors, conveyors, mixers, agricultural machinery and other general industrial equipment.

 

 

IE3, IE4 and IE5: What the Classes Mean

 

Efficiency classes are defined in the international standard IEC 60034-30-1, which covers IE1 to IE5. As a rule of thumb, each step up means noticeably lower losses, which means less wasted energy and less heat in the motor.

The table below shows the efficiency values from MST's Low Voltage AC Motor range (2-pole models):

Rated power Frame IE3 (YE3) IE4 (YE4) IE5 (YE5)
5.5 kW 132S1-2 89.2% 90.9% 92.6%
11 kW 160M1-2 91.2% 92.6% 94.0%
37 kW 200L2-2 93.7% 94.8% 95.8%
75 kW 280S-2 94.7% 95.6% 96.5%
132 kW 315M-2 95.4% 96.2% 96.9%
250 kW 355M-2 95.8% 96.5% 97.2%

The percentage gaps look small, but they add up quickly on a motor that runs all day.

 

 

 

A Worked Example: 75 kW, Running 24/7

 

Take the 75 kW, 280S-2 model running at full load for 8,760 hours a year.

  • IE3 (94.7%) wastes about 4.20 kW as heat.
  • IE4 (95.6%) wastes about 3.45 kW, roughly 18% less than IE3.
  • IE5 (96.5%) wastes about 2.72 kW, roughly 35% less than IE3.

In annual energy terms:

  • Moving from IE3 to IE4 saves about 6,500 kWh per year.
  • Moving from IE4 to IE5 saves a further 6,400 kWh per year.
  • At an industrial tariff of US$0.13/kWh, IE3 to IE5 saves about US$1,680 per year. At €0.20/kWh, it is about €2,590.

Your own numbers will depend on load factor, running hours and local tariffs. Multiply the saving by the expected service life of the motor, then compare it with the price difference between classes. For motors that run around the clock, such as pumps, fans and compressors, the higher class often pays for itself quickly.

 

 

What Regulations Say Right Now

 

Regulation is one of the main reasons buyers are upgrading.

  • European Union: Under Regulation 2019/1781, most 2-, 4-, 6- and 8-pole motors from 0.75 kW to 1000 kW must meet IE3, while larger 2-, 4- and 6-pole motors from 75 kW to 200 kW must meet IE4. The EU is also reviewing this regulation in light of technological progress, with the Commission publishing a call for evidence in August 2025, so requirements may tighten further.
  • United States: From 2027, ODP, TEFC and explosion-proof motors rated 100 to 250 horsepower must reach NEMA Premium 4 (IE4) efficiency, and certain air-over motors face efficiency requirements for the first time.

If you export or sell into these markets, check the power range and enclosure type of your motors against the rules for your destination. One technical point worth knowing: achieving IE4-level efficiency generally means a higher inrush current, which may conflict with traditional locked-rotor current limits. Check the locked-rotor current data and starter sizing before you finalise a purchase.

 

 

Five Checks Before You Buy a Low Voltage AC Motor

 

  • Voltage and frequency. Confirm 380 V, 400 V or 480 V, and 50 Hz or 60 Hz, against your grid.
  • Duty and load profile. Motors running continuously benefit most from IE4 or IE5. Motors that run a few hours a day may not justify the premium.
  • Starting data. Ask for locked-rotor current and torque ratios, especially for higher-efficiency classes.
  • Speed control. If the motor will run on a variable frequency drive, confirm that it supports your speed range and torque mode.
  • Documentation and supply. Confirm the efficiency class, the test standard it is rated to, and the certificates your market requires. Also ask whether the design uses rare-earth permanent magnets, since that affects supply stability. 

 

 

MST Low Voltage AC Motor: IE3, IE4 and IE5 in One Range

 

MST's Low Voltage AC Motor range covers IE3, IE4 and IE5 efficiency classes, so you can match the class to the job instead of overpaying or under-specifying.

  • Rated voltage: 380 V as standard, with 400 V and 480 V available for overseas markets, at 50 Hz or 60 Hz
  • Protection and cooling: IP55 enclosure, IC411 self-ventilation, F-class insulation
  • Duty: S1 continuous operation
  • Noise: 75 dB or below, with low vibration
  • Standards: designed to meet IEC standards and Chinese GB regulations
  • Speed regulation: supports constant torque and constant power modes
  • Flexibility: standardised frame sizes for easy replacement, with voltage, frequency and mounting options that can be customised
  • Typical uses: conveyors, mixers, agricultural machinery, pumps, fans and other fluid machinery

Looking at higher power? See our 400kW Low Voltage High Power Motor. Planning to run on a drive? Take a look at our VFD Asynchronous Motor.

 

 

Get a Quote for Your Low Voltage AC Motor

 

Tell us your rated power, pole number, voltage, frequency, mounting type and destination market. The MST team will recommend an efficiency class, send the full electrical data sheet and provide a quote for your project.

Email sales@milestonemotor.com or send an inquiry through the MST website.