The 355kW VFD motors are voltage range covers 220V to 690V. This goes beyond simple voltage compatibility-our electrical design team optimized the motor's stator winding turns and enameled wire diameter multiple times to accommodate the specific industrial grid conditions of different countries, such as Europe's 400V three-phase voltage and parts of North America's 277V voltage. We also incorporated a wide-range voltage regulator chip into the voltage regulation module to ensure stable output torque across varying input voltages, eliminating power fluctuations due to grid voltage fluctuations. This ensures universal adaptability for global industrial scenarios.
The 355KW VFD motor can flexibly adjust its speed within a range of 0-1470 RPM by adjusting the frequency. This balances the speed to meet production needs while also achieving energy savings and reducing operating costs, ultimately saving customers significant savings. The key lies in our variable frequency drive (VFD) design: the motor rotor is constructed from laminated high-silicon steel sheets, which have an iron loss over 15% lower than ordinary silicon steel sheets. This reduces energy waste caused by hysteresis losses during frequent speed adjustments. Furthermore, a high-precision speed sensor installed on the motor's end cap provides real-time speed feedback to the VFD, keeping the delay between frequency adjustment and speed response to less than 0.05 seconds. This prevents speed overshoot or lag during speed regulation, ensuring production accuracy while further reducing inefficient energy consumption. One customer has calculated that using our VFD motor to drive a water pump can save nearly $3,000 in electricity costs annually compared to a conventional fixed-speed motor.
In terms of protection and insulation, the 355KW VFD motors boasts a base IP55 rating, upgradeable to IP66 upon request. This provides excellent dust and water resistance, and paired with Class F insulation, ensures reliable operation even in harsh operating conditions. This level of protection is achieved through meticulous design. The IP55 version features EPDM rubber seals at the joints. This material is both temperature-resistant and age-resistant, maintaining its sealing performance in environments ranging from -30°C to 80°C. For the IP66 upgrade, the motor housing is double-coated with an epoxy primer and a polyvinyl fluoride topcoat, providing rainproof protection and resistance to acid and alkali corrosion in industrial environments. The Class F insulation utilizes imported mica tape wrapped around the stator windings. Each layer of tape is compacted at 0.2 MPa and then cured at 180°C. This results in a 20% improvement in insulation performance compared to standard Class F insulation. This prevents insulation breakdown even in long-term operation in high-temperature and high-humidity environments.
The 355kW VFD motors supports multiple mounting methods (V1, B3, B5, and B35), providing flexible adaptation to various industrial equipment installation scenarios. The mounting structure was designed with on-site construction convenience in mind. For example, the B3 horizontal mounting base features waist-shaped mounting holes at the bottom. Compared to round holes, this allows for ±5mm of tolerance when adjusting the motor position on-site, eliminating the need for repeated disassembly and realignment. The B5 flange mounting flange is precision milled to within 0.03mm, ensuring coaxiality between the motor and the equipment output shaft during installation and reducing vibration and noise during operation. Regardless of the mounting method, the motor's bearings utilize Swedish SKF deep groove ball bearings, lubricated with high-temperature lithium-based grease. These bearings can withstand greater radial and axial loads, making them suitable for long-term, continuous industrial operation.
The 355kW VFD motor can be driven by a frequency converter (VFD) (which adjusts motor speed by adjusting frequency). We've optimized the winding, phase, and frequency design for precise speed regulation, maximizing energy efficiency and saving customers thousands of dollars in electricity bills annually. Specifically, we utilize a double-layer winding structure, which reduces harmonic losses compared to single-layer windings, making the motor's current waveform closer to a sine wave at different frequencies and avoiding excessive harmonics that can lead to increased motor heating and energy consumption. The phase design precisely calculates the spatial distribution angle of the windings to ensure smoother electromagnetic torque, eliminating torque ripple even at low frequencies and speeds, ensuring stable operation. We've optimized the motor's rated frequency to match the VFD's common output frequency range (0-50Hz/60Hz). We've also incorporated a frequency compensation circuit into the motor. When the VFD output frequency is too low (e.g., below 5Hz), it automatically compensates the excitation current to prevent demagnetization and power loss, ensuring efficient operation across the entire frequency range.
| Type | Rated Output | Rated Current | Rated output Torque | Speed | Locked Torque | Max Torque | Monent of inertia | Weight |
| 0KW) | (A) | (M.m) | (r/min) | Rated Torque | Rated Torque | (kg.m) | (Kg) | |
| YVF2-225M-4 | 45 | 86.7 | 286.5 | 1475 | 2.0 | 2.8 | 0.469 | 308 |
| YVF2-250M-4 | 55 | 106 | 350.1 | 1480 | 2.0 | 2.8 | 0.66 | 404 |
| YVF2-280S-4 | 75 | 141 | 477.5 | 1480 | 1.7 | 2.8 | 1.12 | 530 |
| YVF2-28CM-4 | 90 | 167 | 573 | 1480 | 1.7 | 2.8 | 1.46 | 690 |
| YVF2-3158-4 | 110 | 201 | 700.3 | 1480 | 1.7 | 2.8 | 3.11 | 855 |
| YVF2-315M-4 | 132 | 241 | 840.3 | 1480 | 1.7 | 2.8 | 3.62 | 1055 |
| YVF2-315L1-4 | 160 | 288 | 1018.6 | 1480 | 1.7 | 2.8 | 4.13 | 1040 |
| YVF2-315L2-4 | 200 | 359 | 1273.2 | 1480 | 1.7 | 2.8 | 4.94 | 1340 |
| YVF2-355M-4 | 250 | 449 | 1591.5 | 1490 | 1.7 | 2.8 | 7.62 | 1630 |
| YVF2-355L-4 | 315 | 566 | 2005.3 | 1490 | 1.7 | 2.8 | 7.71 | 1830 |
| YVF2-908-6 | 0.75 | 2.26 | 7.2 | 910 | 1.9 | 2.8 | 0.0029 | 22 |
| YVF2-90L-6 | 1.1 | 3.18 | 10.5 | 910 | 1.9 | 2.8 | 0.0035 | 28 |
| YVF2-100L-6 | 1.5 | 4.21 | 14.3 | 920 | 1.9 | 2.8 | 0.0069 | 33 |
| YVF2-112M-6 | 2.2 | 5.97 | 21 | 935 | 1.9 | 2.8 | 0.0138 | 44 |
| YVF2-1323-6 | 3 | 7.94 | 28.6 | 960 | 1.9 | 2.8 | 0.0286 | 58 |
| YVF2-132M1-6 | 4 | 10.1 | 38.2 | 960 | 1.9 | 2.8 | 0.0357 | 73 |
| YVF2-132M2-6 | 5.5 | 13.4 | 52.5 | 960 | 1.9 | 2.8 | 0.0449 | 82 |
| YVF2-16CM-6 | 7.5 | 17.2 | 71.6 | 970 | 1.9 | 2.8 | 0.0881 | 102 |
| YVF2-160L-6 | 11 | 24.5 | 105 | 970 | 1.9 | 2.8 | 0.116 | 128 |
| YVF2-180L-6 | 15 | 31.7 | 143.2 | 970 | 1.9 | 2.8 | 0.207 | 178 |
| YVF2-200L1-6 | 18.5 | 39.7 | 176.7 | 980 | 1.9 | 2.8 | 0.315 | 224 |
| YVF2-200L2-6 | 22 | 46.3 | 210.1 | 980 | 1.9 | 2.8 | 0.36 | 231 |
| YVF2-225M-6 | 30 | 61.6 | 286.5 | 980 | 1.9 | 2.8 | 0.547 | 300 |
The 355kW VFD motors are suitable for most common industrial applications, including wheeled and belt conveyors requiring precise control, as well as large equipment such as water and slurry pumps that require adjustable speed and torque. Its variable frequency speed control design and industrial-grade durability make it an ideal power source for industrial production processes, improving production efficiency while reducing energy consumption. For example, in belt conveyor applications, some customers previously used ordinary fixed-speed motors. When the amount of material was small, the motor still ran at high speed, resulting in a large amount of electricity waste. After switching to our variable-speed motors, the speed can be adjusted in real time according to the signal fed back by the material sensor - the speed is increased when there is a lot of material, and the speed is reduced when there is less material. This not only saves more than 20,000 yuan in electricity bills a year, but also because the speed matching is reasonable, the wear rate of the conveyor belt is much slower, the replacement cycle of the conveyor belt is extended, and maintenance costs are indirectly saved. In slurry pump applications, because our motors have precise speed regulation, the pump speed can be adjusted according to the slurry concentration, avoiding the problem of the pump body being blocked due to too fast speed when the concentration is high, or the conveying efficiency being affected by too slow speed when the concentration is low. Customers reported that the equipment failure rate has dropped by 30% compared to before.

Hot Tags: 355kw vfd motors, China 355kw vfd motors manufacturers, suppliers, factory, variable frequency motor for constant torque application, variable frequency motor for custom application, variable frequency motor for planer, variable frequency motor for low speed application, variable frequency motor for soft start application, variable frequency motor for variable speed application