What are the common starting methods of high voltage motors

Apr 05, 2024 Leave a message

1. The high-voltage motor starts directly

Direct start is the direct start of the motor at full voltage. If grid conditions permit, direct start can be used. However, in the actual production process, due to the limited capacity of the power grid, direct start is rarely used. Due to the use of direct start, the starting current is large, so that the voltage drop is larger, there is a large impact on the power supply system, if the voltage drop exceeds a certain value, it may lead to the tripping of the superior substation. Therefore, this direct start method is rarely used in actual operation.

 

2. The high-voltage motor series reactor is started

The series reactor start is to connect the reactor in series when the motor starts, so as to limit and reduce the starting current and grid voltage drop when the motor starts, when the motor runs stably and the current reaches a certain value, the removal reactor becomes the direct start mode of the motor. Because the voltage at the motor end also drops during the start-up process, it is easy to cause the starting torque to be insufficient, and there will be a secondary impact process during the start-up process.

 

3. The autotransformer of the high-voltage motor is started

Autotransformer starting refers to the use of autotransformer to reduce the starting voltage applied to the stator winding of the motor when the motor starts. After the motor is started, the motor is separated from the autotransformer, so that it can operate normally at full voltage. The advantage is that different taps on the secondary side of the autotransformer can be selected according to the allowable starting current and the required starting torque to achieve step-down starting, and it can be used regardless of whether the stator winding of the motor adopts the star connection or the triangle connection. The disadvantage is that the device is larger and therefore more expensive.

 

high voltage electric motor 4

 

4. Soft start of high-voltage motor variable resistance

Variable resistor soft start-up includes thermal variable resistance start-up and liquid resistance start-up, which mainly shares part of the voltage drop by inserting a variable liquid resistor in series in the loop. As the start-up time progresses, the voltage drop across the variable resistor decreases, which ultimately leads to a smooth start-up of the high-voltage motor. The variable resistor starting mode has good start-up characteristics in the start-up process, but it is not suitable for frequent start-up.

 

5. Magnetron soft start of high-voltage motor

Magnetron soft start is a three-phase saturated reactor manufactured in series between the power supply and the motor by using the principle of magnetic amplifier, and the excitation current of the magnetic amplifier control winding is adjusted through the digital control board during starting, and the reactance value of the saturation reactor is changed to adjust the starting voltage drop to achieve soft start of the motor.

 

6. High-voltage motor frequency conversion soft start

Frequency conversion soft start is to use the on-off effect of thyristor components to first convert the power frequency AC power supply into DC power supply through the rectifier, and then convert the DC power supply into AC power supply with controllable frequency and voltage to supply the motor to achieve the purpose of stable start. Now, matrix alternating frequency conversion is also being developed. Compared with other starting methods, variable frequency soft start has great advantages, and with the development of technology, it is the most promising high-voltage motor starting method.

 